Eia 364 20 pdf files

May 2, 2008 eia standard tp38ceia36438c cable pullout test procedure for electrical connectors eia36438c revision of eia36438b may 2008 eia standards electronic components association. S311p835 page 4 of 18 rev eca eia 364 21 insulation resistance test procedure for electrical connectors, sockets, and coaxial contacts. Eca eia 364 27 mechanical sock specified pulse test procedure for electrical connectors. Tp20f dielectric withstanding voltage test procedure for. Eia36420 datasheet, eia 364 20 pdf, eia36420 data sheet, eia 364 20 manual, eia 364 20 pdf, eia 364 20, datenblatt, electronics eia 364 20, alldatasheet, free, datasheet, datasheets, data sheet, datas sheets, databook, free datasheet. Eca eia 364 28 vibration test procedure for electrical connectors and sockets. Eia 364 20 and milstd44 both dictate that the dielectric withstanding voltage dwv be established as 75% of the minimum breakdown voltage of the connector breakdown voltage is defined as the voltage at which a connector failure is observed. Eia36420 and milstd44 both dictate that the dielectric withstanding voltage dwv be established as 75% of the minimum breakdown voltage of the connector breakdown voltage is defined as the voltage at which a connector failure is observed. Eia 364 10 fluid immersion test procedure for electrical connectors and sockets eia eca 364 mating and unmating forces test procedure for electrical connectors and sockets eia 364 20 withstanding voltage test procedure for electrical connectors, sockets and coaxial contacts. The test tested according to the standard foundation, tested aspect and obeyed allied editor request. Eia 364 20 datasheet, eia 364 20 datasheets, eia 364 20 pdf, eia 364 20 circuit. Dielectric strength mateunmate connectors, apply 100v ac for 1 minute at sea level. Eia364 establishes a uniform set of industry standards for evaluating the environmental performance of sockets and electrical connectors in controlled environment applications. Eia36410 fluid immersion test procedure for electrical connectors and sockets eiaeca364 mating and unmating forces test procedure for electrical connectors and sockets eia36420 withstanding voltage test procedure for electrical connectors, sockets and coaxial contacts.

Cross reference of eia 364 procedures and mil std 44 methods. This rated voltage is a generalpurpose guideline where no other electrical standard applies. Measurements shall be in accordance with eia 36423. Measurements shall be in accordance with eia 364 23. Controlled environments are classified as no more severe than class number g1. Electrical connectorsocket test procedures including environmental. S311p835 page 4 of 18 rev ecaeia36421 insulation resistance test procedure for electrical connectors, sockets, and coaxial contacts. Unmated connectors shall be tested in accordance with test procedure eia 364 20, condition i. Ecaeia36427 mechanical sock specified pulse test procedure for electrical. Eia364, the insulation resistance between the housing and contact shall be 5,000 m. Our policy towards the use of cookies techstreet, a clarivate analytics brand, uses cookies to improve your online experience. Amsc nafsc 5935mildtl24308gwamendment 21 august 2012supersedingmildtl24308gwamendment 125 january 2011detail specification datasheet search, datasheets, datasheet search site for electronic components and semiconductors, integrated circuits, diodes and other semiconductors.

Product specification chipconnect cable assembly farnell. Eia364 test methods for electrical connectors milg45204 gold plating electrodeposited. Design qualification test report ffsdftsh ffsd25d12. Dielectric withstanding voltage en2591207 eia 36420 with leakage current 5000 m. Connectors, electric, rectangular, nonenvironmental, miniature, polarized shell, rack and panel, general specifcation for, eia 364 20 datasheet, eia 364 20 circuit. Technical data sheet octis power board connector 2 pos pip page 35 issue 201016a series octis part number octi360500. The following documents form a part of this specification to the extent specified herein. Size milliohms 16 5 20 9 22 15 24 20 26 31 28 50 eia36423 100 milliamperes maximum and 20. The test shall be in accordance with eia 364 71b, the contact solder tails must have solder coverage of 95% up.

The covered area must not show any evidence of voids or pinholes. Per eia36452 category 3 the object of this test procedure is to detail a uniform. Working voltage sea level 150 vrms eia 36020 cond i working voltage 70 000 feet 100 vrms eia 36020 cond iv insulation resistance 5,000 m. Petroleum liquids includes distillate and residual fuel oils, jet fuel, kerosene, waste oil, and beginning in 2011, propane. Eia 364 92 2008 tp92 wire bending test procedure for insulation displacement contacts idc for electrical connectors eia 364 96 2002 eia 364 1002 2008 test methodology for assessing the performance of complaint contact terminations used as free standing contacts or in electrical connectors and sockets.

The test board was subjected to a one hour air dry period at ambient temperature. Eia rs 364, tp milstd44, method 20 10935 contact engaging and separating force, test, connectors eia rs 364, tp 6 ipc31 milstd44, method 3004 a s 5 0 10929 withstanding andor breakdown voltage, test procedure for eia rs 364, tp 20 milstd202, method 301 milstd44, method 3001 as 0 2, insulation. Cross reference of eia 364 procedures and mil std 44. Contact resistance eia 364 23 8 milliohms at 3 amps. Solderability of contact terminations test procedure for electrical connectors eia36452 revision b superseded see the following. This eia file type entry was marked as obsolete and no longer supported file format. Itt detail specification,alldatasheet, datasheet, datasheet search site for electronic components and semiconductors, integrated circuits, diodes, triacs, and other semiconductors. The test shall be in accordance with eia36471b, the contact solder tails must have solder coverage of 95% up. The eia file extension is also used for mazatrol, a programming language for mazak cnc machines. The following documents and forms constitute a part of this specification to the extent. The following documents form a part of this specification to the extent. This standard establishes a recommended minimum test sequence and test procedures for electrical connectors and sockets. Insulation resistance data and typical test setup is included in appendix b.

Between adjacent contacts of unmated connector assemblies. Electrical connectorsocket test procedures including. Insulation may degrade if the connector is exposed to repeated dwv tests and the dwv test voltage. Connectors, electric, rectangular, nonenvironmental, miniature, polarized shell, rack and panel, general specifcation for, eia36420 datasheet, eia 364 20 circuit. Ulstd94 tests for flammability of plastic materials for parts in devices and appliances. Magnetic permeability shelltoshell conductivity gage location and retention flammability low temperature. Mechanical shock eia 36427 half sine, 100 gs, 6 milliseconds condition c each axis vibration eia 36428, random vibration 7. Eia36420 datasheet, eia 364 20 datasheets, eia 364 20 pdf, eia 364 20 circuit.

Eia 364 21 insulation resistance test procedure for. This standard also includes administrative details and guidelines for connectorsocket qualification and an annex for pertinent technical information. P6001,p6002, p6003, p6004, p6005, p6006 6p6c, 6p4c,6p2c modular plug 4. Energy information administration, form eia63c, densified biomass fuel report. Final dielectric breakdown voltage was performed in accordance with eia36420. May 2, 2008 eia standard tp38ceia 364 38c cable pullout test procedure for electrical connectors eia 364 38c revision of eia 364 38b may 2008 eia standards electronic components association. This type of file is no longer actively used and is most likely obsolete. For signal contacts, the low level contact resistance shall also not exceed 20 milliohms after any treatment andor environmental exposure. After exposure, the contact solder tails shall have a minimum of 95% solder coverage. Eia 364 54 eta 364 83 eia 364 99 104 eia 364 105 eia 364 106 milstd202 specific test methods test name salt atmosphere humidity moisture resistance thermal shock vibration vibration, high frequency acceleration shock, specified pulse random vibration test paragraph 101 103 106 107 201 204 212 2. Insulation resistance mateunmate connectors, apply 100v dc for 1 minute at sea level between adjacent terminal or ground. Tp20f dielectric withstanding voltage test procedure. Insulation resistance was performed and all measurements were 10 g. The test tested according to the standard foundation, tested aspect and obeyed allied editor request 2.

1489 785 97 926 762 135 1124 1144 314 1142 855 61 1565 1502 6 1558 201 392 637 1451 396 1552 986 1393 204 1370 108 533 1168 881 1593 687 270 480 1612 370 1472 1372 733 1281 1498 1463 964 1348 17 1349 1229